Vedere la pagina 118
OBD 107
SNAPSHOT SAVE
After completion of the data capture, the snapshot can be saved for later review.
Press y to save this data set or n to continue without saving the data. The current
snapshot can be reviewed immediately even if not saved.
ACTIVE KEYS
y Save snapshot data.
n Continue to Data Display phase without saving snapshot data.
DATA DISPLAY PHASE
At the completion of the data capture phase, <Sample> and a time stamp are displayed at
the bottom of the screen. The trigger point is indicated by a sample of 0.0 sec. All data
samples have a time stamp relative to the trigger. For a 50% trigger and 30-second data
capture, the Tester displays samples from -15.0 seconds to 15.0 seconds.
Data captured in the Snapshot mode can be displayed in all of the formats that are
available in the <DATA LIST> mode, except for Strip Chart.
ACTIVE KEYS
u d Move the display up or down one parameter.
Au Move the display one page. (<DATA LIST> mode only.)
Ad
l r Sequence through the sample displayed.
y Change the highlighted parameter to the next parameter in the list. (<LED/
LIST>, <BAR GRAPH> and <LINE GRAPH> modes only.)
n Change the highlighted parameter to the previous parameter in the list.
(<LED/LIST>, <BAR GRAPH>, and <LINE GRAPH> modes only.)
AY Change to the next parameter not currently displayed. (<LED/LIST>, <BAR
GRAPH>, and <LINE GRAPH> modes only.)
AN Change to the previous parameter not currently displayed. (<LED/LIST>,
<BAR GRAPH>, and <LINE GRAPH> modes only.)
! Go to <DATA LIST> mode.
@ Go to <LED/LIST> mode.
# Go to <BAR GRAPH> mode.
$ Go to <LINE GRAPH> mode.
( Change between large and compressed character size.
) Turn cursor on and off.
Ah Display parameter information.
s Print data list.
HINT
The snapshot data is stored on the Program Card. Make sure
that the same Program Card is used when reviewing stored
snapshot data.