SPECTRA SERIES 49
12.7 FORCE ARMING
Force Arming allows users to rapidly arm the system, without having to wait for all zones in the system to be closed.
Force Arming is commonly used when a motion detector is protecting the area occupied by a keypad. Therefore,
when arming the system, if the motion detector is set as a Force Zone, the control panel will ignore the zone and
allow users to arm the system even if the zone is open. Any open Force Zones at the time of arming will be
considered deactivated by the control panel. If during this period a deactivated zone is closed, the control panel will
revert that zone to active status, hence, will generate an alarm if breached. UL Note: Not to be used with UL
installations
If you make a mistake, the keypad will emit a Rejection Beep. When correctly Force Armed, the appropriate arm
indication appears and the Exit Delay will initiate. Please note that Force Arming can also be activated using One-
Touch Force Armi ng. Also, note that the User Access Code must have the For ce Arming Option enabled.
12.8 MANUAL BYPASS PROGRAMMING
Manual Bypass Programming allows users to program the alarm system to ignore (deactivate) specified zones the
next time the system is armed. The Access Code must have the Bypass Programming Option enabled. Please note
that Fire Zones cannot be bypassed. Manual Bypass Programming can also be activated using One-Touch Bypass
Programming.
12.8.1 BYPASS RECALL FEA TUR E
After disarming the system, the control panel will erase the bypass entries. By using the Bypass Recall
Feature, you can reinstate the previous bypass entries saved in memory. This eliminates the need to
manually program the bypass entries every time you arm the system. The Access Code must have the
Bypass Programming Option enabled.
12.9 ONE-TOUCH ARMING
On e- Tou ch Arming allows users to arm the system without using an access code. Simply press and hold a key. One-
Touch Arming can be used to allow specific individuals like service personnel (i.e. cleaners, maintenance) to arm the
system when leaving the protected area, without giving them access to any other alarm system operations.
How Do I Force Arm?
1) All zones in the desired partition (except Force Zones) must be closed.
2) Press the [FORCE] key
3) Key in a valid [ACCESS CODE]*
*IF YOU HAVE ACCESS TO BOTH PARTITIONS
:
Press the key corresponding to the partition you wish to Force Arm. To arm both partitions, pr ess the [1] key then
after the Confirmation Beep press the [2] key.
How do I Program Bypass Entries?
1) Press the [BYP] key.
2) Key in a valid [ACCESS CODE]*
3) Select one or more [ZONES] you wish to bypass
4) Once you have entered the desired bypass entries, press the [ENTER] key to accept these entries.
*IF YOU HAVE ACCESS TO BOTH PARTITIONS
:
Press the key corresponding to the desired partition.
How Do I Recall Bypass Entries?
1) Press the [BYP] key.
2) Key in your [ACCESS CODE]*
3) Press the [BYP] key. Previously bypassed zones will illuminate.
4) Press the [ENTER] key.
*IF YOU HAVE ACCESS TO BOTH PARTITIONS
:
Press the key corresponding to the desired partition.